LSA
- protection for 1 or 10 lines/pair
- also available in other voltage levels, for instance 24V
- for installation on Krone connectors
- Shortcut by fault
Technical data
| Maximum line voltage | 170V (Max 185 VDC) |
| Maximum discharge current (8/20µs) | 15kA |
| Residual voltage | 220V |
| Max line current | 200mA |
| Temperature | -25oC to +60oC |